News
Home News News Plate Heat Exchanger Maintenance/cleaning

Plate Heat Exchanger Maintenance/cleaning

Release time:2025-09-19     Visits:31

Cleaning method for scaling of plate heat exchangers:

1. Selection of cleaning agents

The current choice of cleaning agent is acid washing, which includes both organic and inorganic acids. Organic acids mainly include oxalic acid, formic acid, etc. Inorganic acids mainly include hydrochloric acid, nitric acid, etc. Based on the analysis of scaling and process, material, and scale composition of the heat exchanger, it is concluded that:

1) The heat exchanger has a small flow area and a complex internal structure, making it difficult to discharge the cleaning solution if it settles.

2) The material of the heat exchanger is nickel titanium alloy, and hydrochloric acid is used as the cleaning solution, which can easily cause strong corrosion to the plates and shorten the service life of the heat exchanger.

Through repeated experiments, it has been found that choosing formic acid as the cleaning solution has a good effect. Adding buffering agents and surfactants to formic acid cleaning solution has a good cleaning effect and can reduce the corrosion of the cleaning solution on the plate. Chemical experiments on scale samples have shown that formic acid can effectively remove scale. Through acid immersion tests, it was found that formic acid can effectively remove scale attached to the plates, and its corrosion effect on the heat exchanger plates is also minimal.

2. The basic principle of removing scale

1) Dissolving effect: Acid solutions are prone to react with calcium, magnesium, and carbonate scale, generating soluble compounds that dissolve the scale.

2) Stripping effect: Acid solution can dissolve oxides on the metal surface, breaking the bond with scale. Thus, the scale adhering to the surface of the metal oxide is peeled off. And it fell off.

3) Gas lifting effect: After the acid solution reacts with calcium, magnesium, and carbonate scale, a large amount of carbon dioxide is produced. Carbon dioxide gas is escaping during the process. For scale layers that are difficult to dissolve or dissolve slowly, there is a certain lifting force that causes the scale to detach from the heated surface of the heat exchanger.

4) Loosening effect: For scale containing a mixture of silicates and sulfates, residual scale becomes loose due to the dissolution of calcium, magnesium, carbonate, and iron oxides in acidic solutions, making it easily washed away by flowing acidic solutions.

3. Process requirements for cleaning scale

1) Pickling temperature: Increasing the pickling temperature is beneficial for improving the descaling effect. If the temperature is too high, it will intensify the corrosion of the pickling solution on the heat exchanger plate. Through repeated experiments, it has been found that the pickling temperature should be controlled between 60 ° C and E.

2) Acid pickling solution concentration: According to repeated experiments, the acid pickling solution should be prepared at a concentration of 81.0% formic acid, 17.0% water, 1.2% buffering agent, and 0.8% surfactant to achieve good cleaning effect.

3) Acid washing method and time: The acid washing method should be carried out by combining static soaking and dynamic cycling. The pickling time is static soaking for 2 hours, followed by dynamic cycling for 3-4 hours. During the pickling process, samples should be taken frequently to test the pickling concentration. When the difference in concentration between adjacent tests is less than 0.2%, the pickling reaction can be considered complete.

4) Passivation treatment: After acid pickling, most of the scale and metal oxides on the surface of the plate heat exchanger are dissolved and peeled off, exposing new metal that is prone to corrosion. Therefore, after acid pickling, the heat exchanger plates are passivated.

4. Specific steps for cleaning scale

1) Washing: Before pickling, the heat exchanger should be washed in an open manner to ensure that there are no impurities such as mud or scale inside the heat exchanger. This can improve the pickling effect and reduce the acid consumption.

2) Pour the cleaning solution into the cleaning equipment and then inject it into the heat exchanger.

3) Acid washing: Soak the heat exchanger filled with acid solution in a static state for 2 hours. Then continuously cycle it dynamically for 3-4 hours. During this period, clean it alternately in both directions every 0.5 hours. After acid washing, if the pH value of the acid solution is greater than 2, the acid solution can be reused. Otherwise, the acid solution should be diluted and neutralized before being discharged.

4) Alkali washing: After the acid washing is completed, prepare NaOH, Na, PO, and softened water in a certain proportion, and use dynamic circulation to perform alkali washing on the heat exchanger to achieve acid-base neutralization and prevent corrosion of the heat exchanger plates.

5) Water washing: After alkaline washing, rinse the heat exchanger repeatedly with clean softened water for 0.5 hours to thoroughly remove any residue inside the heat exchanger.

6) Record: During the cleaning process, the time of each step should be strictly recorded to check the cleaning effect. In short, after cleaning, a pressure test should be conducted on the heat exchanger. Only qualified products can be used.

5. Measures to prevent scaling of plate heat exchangers

1) Strictly control the water quality during operation, conduct rigorous water quality testing on the water in the system and the softened water in the softening tank, and only inject it into the pipeline network after passing the test.

2) When the new system is put into operation, the heat exchanger should be separated from the system and cycled for a period of time before being integrated into the system to avoid impurities from the pipeline entering the heat exchanger.

3) In the entire system, in addition to regular cleaning of the dirt remover and filter, the cleanliness of the pipeline network should also be maintained to prevent blockage of the heat exchanger.

Our factory has been established for many years. With our ability to produce molds and the favorable conditions for self production of rubber pads, we have provided maintenance services to hundreds of imported board replacement customers in China. You just need to exchange the old version to our factory, and we will provide you with service.


Need Help?

Whether you are inquiring about product specifications, requesting samples, or seeking customized plate heat exchanger spare parts,our technical team is always ready to provide rapid response and precise support.

Contact Us

Hi~ How can I help you?